4000 Series II - EASi-COM II User Guide
STA0309 - Issue 2.0 Page 17 of 30
3. THE 1310 CONTROL PANEL (1RU)
3.1 Overview
The EASi-COM 1310 Control Panel is a 1RU by 19-inch rack mounting unit. The Matrix
powers the Control Panel for distances up to 150m but for greater distances the panel
can be powered from an external supply. The panel can then be located at distances
up to 500m, depending on cable type.
The Control Panel features sixteen pushbutton Direct Access Keys (DAK) which allow
communication with all ports in the system. The DAKs can be programmed to have
separate Talk and Listen actions or a combined Talk + Listen action. All programming
is lost when power is removed, but jumpers on the Control Panel circuit board can set
the power on defaults.
The 1310 - 16 Key Control Panel Level Control Panel has the following features:
16 pushbutton Direct Access Keys
Programmable pushbuttons for talk, listen, and talk + listen functions
Loudspeaker output jack
Separate audio inputs and level controls for Main Intercom and Production Talk-
back/Programme
DC powered from the Matrix or an external power supply
Audio and control interface options
Full signalisation of send and receive routes
Plug-in microphone or headset operation
Microphone gain, headset gain and side-tone adjustment at rear
Headset connector with pushbutton select
Designation strip for key identification