4
INSTALLATION
5
CABLE TV CHANNELS
Channel
Number
Center of
Channel
EIA/NCTA
Numeric
Equivalent
Frequency
in MHz
2
3
4
5
6
57
63
69
79
85
95
96
97
98
99
93
99
105
111
117
14
15
16
17
18
123
129
135
141
147
19
20
21
22
153
159
165
171
7
8
9
10
11
12
13
177
183
189
195
201
207
213
23
24
25
26
27
219
225
231
237
243
28
29
30
31
32
249
255
261
267
273
33
34
35
36
279
285
291
297
CABLE TV CHANNELS
Channel
Number
Center of
Channel
EIA/NCTA
Numeric
Equivalent
Frequency
in MHz
37
38
39
40
41
303
309
315
321
327
42
43
44
45
46
333
339
345
351
357
47
48
49
50
51
363
369
375
381
387
52
53
54
55
56
393
399
405
411
417
57
58
59
60
61
423
429
435
441
447
62
63
64
65
66
453
459
465
471
477
67
68
69
70
71
483
489
495
501
507
72
73
74
75
76
513
519
525
531
537
77
78
543
549
CABLE TV CHANNELS
Channel
Number
Center of
Channel
EIA/NCTA
Numeric
Equivalent
Frequency
in MHz
79
80
81
82
83
555
561
567
573
579
84
85
86
87
88
585
591
597
603
609
89
90
91
92
93
615
621
627
633
639
94
100
101
102
103
645
651
657
663
669
104
105
106
107
108
675
681
687
693
699
109
110
111
112
113
705
711
717
723
729
114
115
116
117
118
735
741
747
753
759
119
120
121
122
123
765
771
777
783
789
124
125
126
127
128
795
801
807
813
819
129
130
131
132
133
825
831
837
843
849
134
135
855
861
CONNECTIONS AND CONTROLS
All connections to and from each upconverter
are made thro ugh the rear panel.
DESCRIPTION
Figure 3 sho ws a typical installation utilizing 4
DUC864 upconverters used with 4 TMQAM
modulators. A PS8 power supply module is
used to power all units.
RACK MOUNTING
Adequate ventilation is very important in
multichannel installations. Units should be
spaced apart by at least o ne panel height
wherever possible, and some air movement is
mandatory in enclosed rack cabinets. Exces-
sive heat will shorten component life and
modulator performance will be degraded
without
proper cooling.
DUC864
UPCONVERTERS
QAM MODULATOR
UNITS
IF IN
POWER
+12 V
GND
+5 V
44 MHz
IF O U T P UT
ASI T RANSPO RT
STREA M
INPUT
POWER
IF IN
POWER
+12 V
GND
+5 V
44
MHz
IF O U T P UT
ASI T RANSPO RT
STREA M INP UT
POWER
IF IN
POWER
+12 V
GND
+5 V
44 MHz
IF O U T P UT
ASI T RANSPO RT
STREA M
INPUT
POWER
IF IN
POWER
+12 V
GND
+5 V
44 MHz
IF O U T P UT
ASI T RANSPO RT
STREA M
INPUT
10 0- 240
V
~
50 /6 0 Hz
85
WATTS
PO WE R
DC O UTPUT S X 8
12V GND 5V
RF O UT
+12 V
GND
+5 V
RF O UT
+12 V
GND
+5 V
RF O UT
+12 V
GND
+5 V
RF O UT
+12 V
GND
+5 V
DC
OUTPU T
RAT ING.
TOTAL
OF ALL OUTPUT S:
+5V:6 A
MAX.
+12V:2.5A
MAX.
FROM SATELLITE
DEMODULATOR OR
OTHER ASI DATA
STREAM
TO QAM
DISTRIBUTION
Figure 3
AC POWER
CONNECTOR
Seitenansicht 7
1 2 3 4 5 6 7 8