The negative bias supply uses a IN3194 diode to provide -60 volts
to the AVC system for minimum bias, muting, and control of RF Gain.
An
OB2
voltage regulator VII is incorporated to provide 108 volts regulated for
operation of the xtal calibrator.
A
IN714
zener diode, in conjunction with
V11
provides
10
volts regulated for the VFO and H .F. oscillator.
The power transformer has a dual primary.
As supplied, it is connected
in parallel for 120 volt operation.
To operate at 240 volts, it will be
necessary to remove the GRN/BLACK and YEL/BLACK wires from their
present terminals and connect them together at the remaining terminal
of the terminal strip.
This places the windings in series.
It will also be necessary to remove the.75 amp fuse and replace it with
a
.4
amp slo-blo fuse.
m
r
--
Figure #8
-26-