DRAKE R-4C Spezifikationen Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 29
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
f. Set AF GAIN knob to a comfortable level.
g. Set PRESELECTOR control to center of band
segment marked on panel. After desired signal is
tuned in, adjust for maximum S meter reading.
3-17. SSB RECEPTION.
a. Make the basic control settings listed above.
b. Set MODE switch to SSB.
c. Set
PASSBAND
TUNING to the dot at either
the LSB or USB position as desired.
d. Set AGC switch to S.
e. Tune in station with Main Tuning knob.
f. Adjust PRESELECTOR for maximum S meter
reading.
After tuning in a station as described above, addi-
tional adjustments may be made to further improve
reception under various conditions or operator
preferences.
g. Normally the AGC time constant S is optimum
for SSB but for rapidly changing signal condi-
tions, it may be desirable to switch to the AGC
release time constant M. The F or OFF positions
will not normally be desirable for SSB reception.
h. The PASSBAND TUNING control may be
ad-
Under extremely adverse interference conditions
the 1.5 kHz bandwidth crystal filter may be used
to advantage for SSB reception if this accessory
filter has been installed. Careful adjustment of
the
PASSBAND
TUNING control will aid in the
effective use of this restricted bandwidth for
SSB reception.
The NOTCH control may be used to attenuate
an interfering heterodyne. See paragraph 3-l 2
for adjustment of this control.
k. If impulse type noise interference is a problem,
the accessory 4-NB Noise Blanker may be
installed. The Noise Blanker may then be activa-
ted by placing the FUNCTION switch in the NB
position.
justed
slightly away from the dot at the LSB or
USB position to emphasize low or high frequen-
cies. The fine adjustment of this control is large-
ly one of operator preference, and the setting
should be the one which produces the most
pleasing audio response or minimum interference.
3-18 CW RECEPTION.
a.
Make the basic control settings listed in para-
graph 3-l6.
b.
Set the MODE switch to SSB if the 2.4 kHz
bandwidth filter is desired. If one of the narrow-
er bandwidth accessory crystal filters has been
installed it may be selected with the MODE
switch.
C.
Set the PASSBAND TUNING to the dot at LSB
or USB if the SSB mode is used. If the 1.5 kHz
accessory bandwidth is used, set this control just
beyond one end of the second longest line. If the
500 Hz or 250 Hz filter is used, set the
PASS-
BAND TUNING just beyond one end of the
shortest line.
d.
e.
f.
Set the AGC switch to S.
Tune in a CW signal with Main Tuning knob for
maximum S meter reading.
Adjust PRESELECTOR for maximum S meter
reading.
After tuning in a station as described above, addi-
tional adjustments may be made as follows:
If a different frequency beat note is desired, re-
tune the MAIN TUNING for desired beat note
while keeping the signal peaked for maximum
strength with the PASSBAND TUNING control.
Faster AGC release time constants may be selec-
ted with the AGC control. If desired, the AGC
may be switched OFF and the gain controlled
manually with the RF GAIN lever.
The NOTCH control may be used to attenuate
interfering undesired heterodynes. See paragraph
3-l 2 for adjustments of this control.
The accessory 4-NB Noise Blanker may be used
if impulse noise interference is a problem.
3-19. AM RECEPTION.
Make the basic control settings listed in para-
graph 3-16.
Set MODE switch to AM.
Tune in station for maximum S meter indication.
d. Peak PRESELECTOR for maximum signal
strength.
3-6
Seitenansicht 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 28 29

Kommentare zu diesen Handbüchern

Keine Kommentare