the notch control at 12 o’clock and adjust the main tuning knob for max-
imum AVC voltage
(
positive going
)
.
Altemately adjust the notch control
and the notch depth control, R57, for maximum AVC voltage (positive
going
)
.
5.3.5
S-METER
ADJUSTMENT
Tune
in a 10,000 microvolt signal on 7.2 MHz LSB and looking into the
top of the
chassis
with the front panel
facing
you,
adjust R73, the left
control on the S-meter circuit board for + 4.5 volts on the middle top ter-
minal of the
meter
board and has a
white/black
tracer wire
connected
to
it
.
Remove the 10,000 microvolt signal and adjust R64, the right control
for
meter
zero .
Because these controls interact slightly, repeat the above
procedure
until no further interaction occurs .
-