SPR-4 R.F.
VOLTAGE CHART
Trans is tor
Q1
Q4
Q7,
Q8
Q10
Q23
Q24
Q5
Q11
Q17
Q21
Q27
Function
Loop Amp
RF Amp
1st Mixer
2nd Mixer
1st IF Amp
2nd IF Amp
Range Xtal
Osc.
Premixer
Xtal
Osc.
Xtal
Osc.
Buffer
Neg .
Supply Driver
BF0
Drain
Collector
131”
16
215**
900**
310
1V
4V
2.5V
3V
2.8V
4.25V
T
Gate 1
2.15V
Gate
i
480
Source
1.35V
All
voltages are millivolts RMS
except
those marked V (volts)
MEASUREMENT CONDITIONS
Set signal generator to 7.0 MHz and 1 millivolt at the SPR-4 antenna
jack.
Tune
in generator on LSB for maximum S-meter reading with RF
Gain
fully
clockwise and accessory switch on NORM and notch in OFF
position.
Measurements taken without 5-NB installed . Boonton Mode1
91 CA RF voltmeter used.
100:l
divider used on measurements above
500
mV.
*
SPR-4 tuned to 1 MHz LSB with 1 millivolt R.F.
across
external
47 ohm
emitter
resistor .
Measurement of generator output must be
done
with SPR-4 turned off.
**
Large variations (-50% + 100%) from values shown are typical.
-